Cardiogramme Echographie Salle d'opération Salle d'opération
Logo   Accueil | Table des matières | Téléchargements | Liens |   Mentions légales   | Contact |Abréviations
Logo  

Bibliographie

Lectures conseillées

AUGOUSTIDES JGT. Advances in the management of carotid artery disease: focus on recent evidence and guidelines. J Cardiothorac Vasc Anesth 2012; 26:166-71
ERICKSON KM, COLE DJ. Carotid artery disease: stenting vs endarterectomy. Br J Anaesth 2010; 105:134-49
MURAD MH, SHAHROUR A, SHAH ND, et al. A systematic review and meta-analysis of randomized trials of carotid endarterectomy vs stenting. J Vasc Surg 2011; 53:792-7
PENNEKAMP CWA, MOLL FL, De BORST GJ. The potential benefits and the role of cerebral monitoring in carotid endarterectmy. Curr Opin Anaesthesiol 2011; 24:693-7


Références

1 ACAS – Endarterectomy for asymptomatic carotid artery stenosis. Executive committee for asymptomatic carotid artery stenosis study. JAMA 1995; 273:1421-8
2 ACKERSTAFF RGA, VANDEVLASAKKER CJW. Monitoring of brain function during carotid endarterectomy: An analysis of contemporary methods. J Cardiothorac Vasc Anesth 1998; 12:341-7
3 ASSADIAN A, Senekowitsch C, Assadian O, et al. Perioperative morbidity and mortality of carotid artery surgery under loco-regional anaeshtesia. Vasa 2005; 34:41-5
4 BATES ER, BABB JD, CATES CU, et al. ACCF/SCAL/SVMB/SIR/ASITN 2007 clinical expert consensus document on carotid stenting. J Am Coll Cardiol 2007; 49:126-70
5 BILLER J, FEINBERG WM, CASTALDO JE, et al. Guidelines for carotid endarterectomy: A statement for healthcare professionals from a special writing group of the Stroke Council, American Heart Association. Stroke 1998; 29:554-62
6 BLACKER DJ, FLEMMING KD, LINK MJ, et al. The preoperative cerebrovascular consultation: common cerebrovascular questions before general or cardiac surgery. Mayo Clin Proc 2004; 79:223-9
7 BONATI LH, EDERLE J, McCABE DJ, et al. Long-term risk of carotid restenosis in patients randomly assigned to endovascular treatment or endarterectomy in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS): long-term follow-up of a randomized trial. Lancet Neurol 2009; 8:908-17
8 BONNET F, DEROSIER JP, PLUSKWA F, et al. Cervical epidural anaesthesia for carotid artery surgery. Can J Anaesth 1990; 37:353-8
9 BORGER MA, FREMES SE, WEIDEL RD, et al. Coronary bypass and carotid endarterectomy: Does a combined approach increase risk ? A meta-analysis. Ann Thorac Surg 1999; 68:14-21
9a BROTT TG, HOBSON RW, HOWARD G, et al. Stenting versus endarterectomy for treatment of carotid-artery stenosis. N Engl J Med 2010; 363:11-23
10 BROWN MM, EDERLE J, BONATI LH, et al. Safety results of the International Carotid Stenting Study (ICSS): early outcome of patients randomised between stenting and endarterectomy for symptomatic carotid stenosis. Cerebrovasc Dis 2009; 27(suppl 6):10
11 CAPES SE, HUNT D, MALMBERG K, et al. Stress hyperglycemia and prognosis of stroke in nondiabetic and diabetic patients: A systematic overview. Stroke 2001; 32:2426-32
12 CHAMBERS BR, NORRIS JW. Outcome in patients with asymptomatic neck bruits. N Engl J Med 1986; 315:860-5
13 CHASSOT PG, DELABAYS A, SPAHN DR. Preoperative evaluation of patients with, or at risk of, coronary artery disease undergoing non-cardiac surgery. Brit J Anaesth 2002; 89:747-59
14 CHATURVEDI S, BRUNO A, FEASBY T, et al. Carotid endarterectomy – an evidence based review: Report of the Therapeutics and technology assessment subcommittee of the American Academy of Neurology. Neurology 2005; 65:794-801
15 CHIESA R, MELISSANO G, CASTELLANO R, et al. Carotid endarterectomy: experience in 5’425 cases. Am Vasc Surg 2004; 18:527-34
16 CUADRA SA, ZWERLING JS, FEUERMAN M, et al. Cerebral oximetry monitoring during endarterectomy: effect of carotid clamping and shunting. Vasc Endovasc Surg 2003; 37:407-13
17 Cywinski JB, Koch CG, Krajewski LP, et al. Increased risk associated with combined carotid endarterectomy and coronary artery bypass graft surgery: A propensity-matched comparison with isolated coronary artery bypass graft surgery. J Cardiothorac Vasc Anesth 2006; 20:796-802
18 DAS SK, BROW TD, PEPPER J. Continuing controversy in the management of concomitant coronary and carotid disease: An overview. Int J Cardiol 2000; 74: 47-65
19 DAVIS DH, SUNDT TM. Relationship of cerebral blood flow to cardiac output, mean arterial pressure, blood volume, and alpha and beta blockade in cats. J Neurosurg 1980; 52:745-54
20 DELLAGRAMMATICAS D, GOUGH MJ. Management of concommittant carotid and coronary disease. In: HOWELL S, et al, eds. Heart disease and the surgical patient. New York:Informa Healthcare, 2007, 293-303
21 DEOGAONKAR A, VIVAR R, BULLOCK RE, et al. Bispectral index monitoring may not reliably indicate cerebral ischaemia during awake carotid endarterectomy. Br J Anaesth 2005; 94:800-4
22 DeSOUZA AA, FILHO MA, FAGLIONE W, CARVALHO GT. Superficial versus combined cervical plexus block for carotid endarterectomy: a prospective, randomized study. Surg Neurol 2005; 63:(Suppl 1):S22-5
23 DOBLAR DD. Cerebrovascular assessment of the high-risk patient: The role of transcranial Doppler ultrasound. J Cardiothorac Vasc Anesth 1996; 10:3-14
24 EAGLE KA, RIHAL CS, MICKEL MC, et al. Cardiac risk of non-cardiac surgery: influence of coronary disease and type of surgery in 3,368 operations. Circulation 1997; 96:1882-7
25 ECKSTEIN HH, RINGLEB P, ALLENBERG JR, et al. Results of the Stent-Protected Angioplasty versus Carotid Endarterectomy (SPACE) study to treat symptomatic stenoses at 2 years: a multinational, prospective, randomised trial. Lancet Neurol 2008; 7:893-902
26 ECST: European Carotid Surgery Trialist’s Collaborative Group – Randomised trial of endarterectomy for recently symptomatic carotid stenosis: final results of the MRC European Carotid Surgery Trial. Lancet 1998; 351:1379-87
27 EDMONDS HL. Advances in neuromonitoring for cardiothoracic and vascular surgery. J Cardiothorac Vasc Anesth 2001; 15:241-50
28 EDMONDS HL, GANZEL BL, AUSTIN EH. Cerebral oximetry for cardiac and vascular surgery. Semin Cardiothorac Vasc Anesth 2004; 8:147-66
28a ERICKSON KM, COLE DJ. Carotid artery disease: stenting vs endarterectomy. Br J Anaesth 2010; 105:134-49
29 EVANS BA, WIJDICKS EF. High-grade carotid stenosis detected before general surgery: is endarterectomy indicated ? Neurology 2001; 57:1328-30
30 FAIRHEAD JF, ROTHWELL PM. The need for urgency in identification and treatment of symptomatic carotid stenosis is already established. Cerebrovasc Dis 2005; 19:355-8
31 FERGUSON GG, ELIASZIW M, BARR HW, et al. The North American Symptomatic Carotid Endarterectomy Trial (NASCET): surgical results in 1415 patients. Stroke 1999; 30:1751-8
32 FLEISHER LA, BECKMAN JA, BROWN KA, et al. ACC/AHA 2007 Guidelines on perioperative cardiovascular evaluation and care for non-cardiac surgery: Executive summary. Anesth Analg 2008; 106:685-712
33 GALA Trial Collaborative Group. General anaesthesia versus local anaesthesia for carotid surgery (GALA): a multicentre, randomised controlled trial. Lancet 2008; 372:2132-42
34 GRANTON JT, GELB AW. Neuroprotection during carotid endarterectomy. Semin Cardiothorac Vasc Anesth 2002; 6:21-5
35 GUAY J. Regional or general anesthesia for carotid endarterectomy ? Evidence from published prospective and retrospective studies. J Cardiothorac Vasc Anesth 2007; 21:127-32
35a GUAY J, OCHROCH EA. Carotid endarterectomy plus medical therapy or medical therapy alone for carotid arterx stenosis in symptomatic or asymptomatic patients: a meta-analysis. . J Cardiothorac Vasc Anesth 2012; 26: 000 (in press)
36 GURER O, YAPICI F, ENC Y, et al. Local versus general anesthesia for carotid endarterectomy: report of 329 cases. J Vasc Endovasc Surg 2003; 37:171-7
37 HALM EA, HANNAN EL, ROJAS M, et al. Clinical and operative predictors of outcomes of carotid endarterectomy. J Vasc Surg 2005; 42:420-8
38 HANS S, JAREUNPOON O. Prospective evaluation of electroencephylography, carotid artery stump pressure, and neurologic changes during 314 consecutive carotid endarterectomies performed in awake patients. J Vasc Surg 2007; 45:511-5
39 HANSEN TD, WARNER DS, TODD MM, et al. Effects of nitrous oxide and volatile anaesthetics on cerebral blood flow. Brit J Anaesth 1989; 63:290-5
40 HOWELL SJ. Carotid endarterectomy. Br J Anaesth 2007; 99:119-31
40a ILLUMINATI G, RICCO JB, CALIO F, et al. Short-term results of a randomized trial examining timing of carotid endarterectomy in patients with severe asymptomatic unilateral stenosis undergoing coronary artery bypass grafting. J Vasc Surg 2011; 54:993-9
41 KOEHLER RC, TRAYSTMAN RJ. Bicarbonate ion modulation of cerebral blood flow during hypoxia and hypercapnia. Am J Physiol 1982; 243:H33-40
42 LAL BK, BROTT TG. The Carotid Revascularisation Endarterectomy vs. Stenting Trial completes randomization: lessons learned and anticipated results. J Vasc Surg 2009; 50:1224-31
43 LEE JW, POMPOSELLI F, PARK KW. Association of sex with perioperative mortality and morbidity after carotid endarterectomy for asymoptomatic carotid stenosis. J Cardiothorac Vasc Anesth 2003; 17:10-16
44 LEVICK JR. An introduction to cardiovascular physiology. 2nd edition. Oxford, Butterworth-Heinemann, 1995, 255-75
45 LOVE A, HOLLYOAK MA. Carotid endarterectomy and local anesthesia: reducing the disasters. Cardiovasc Surg 2000; 8:429-35
46 MADI-JEBARA S, YAZIGI A, SLEILATY G, et al. Staged anesthesia for combined carotid and coronary artery revascularization: A different approach. J Cardiothorac Vasc Anesth 2006; 20:803-6
47 MAHARAJ R. A review of recent developments in the management of carotid artery stenosis. J Cardiothorac Vasc Anesth 2008; 22:277-89
47a MAHMOUDI M, HILL PC, XUE Z, et al. Patients with severe asymptomatic carotid artery stenosis do not have a higher risk of stroke and mortality after coronary artery bypass surgery. Stroke 2011; 42:2801-48 MARROCCO-TRISCHITTA MM, TIEZZI A, SVAMPA MG, et al. Perioperative stress response to carotid endarterectomy: The impact of anesthetic modality. J Vasc Surg 2004; 39:1295-304
49 MARSCHALL KE, VAITKEVICIUTE I. Carotid endarterectomy, carotid artery shunting and outcome: an historical perspective. Curr Opin Anesthesiol 2004; 17:183-7
50 MAS JL, CHATELLIER G, BEYSSEN B, et al. Endarterectomy versus stenting in patients with symptomatic severe carotid stenosis. N Engl J Med 2006; 355:1660-71
51 McCARTHY J, TRIGG R, JOHN C, et al. Patient satisfaction for carotid endarterectomy performed under local anaesthesia. Eur J Vasc Endovasc Surg 2004; 27:654-9
52 McCLEARY AJ; MARITATI G; GOUGH MJ. Carotid endarterectomy: local or general anesthesia ? Eur J Vasc Endovasc Surg 2001; 22:1-12
53 McGIRT MJ, PERLER BA, BROOKE SB, et al. 3-Hydroxy-3-methyl-glutaryl coenzyme A reductase inhibitors reduce the risk of perioperative stroke and mortality after carotid endarterectomy. J Vasc Surg 2005; 42:829-36
54 MELLIERE D, DESGRANGES P, BECQUEMIN JP, et al. Surgery of the internal carotid: locoregional or general anesthesia ?. Ann Chir 2000; 125:530-8
55 MENON DK. Cerebral circulation. In: PRIEBE HJ, SKARVAN K. Cardiovascular physiology, London, BMJ Publishing Group, 1995 pp 198-223
56 MICHENFELDER JD. Anesthesia and the Brain. Clinical, functional, metabolic and vascular correlates. Churchilll Livingstone, New-York, 1988, p 4
57 MILLE T, TACHIMIRI ME, KLERSY C, et al. Near infrared spectroscopy monitoring during carotid endarterectomy: which threshold value is critical ? Eur J Vasc Endovasc Surg 2004; 27:646-50
58 MOORE WS. MOHR JP, NAJAFI H, et al. Carotid endarterectomy. Practice guidelines. J Vasc Surg 1992; 15:469-79
59 MORITZ S, KASPRZAK P, ARIT M, et al. Accuracy of cerebral monitoring in detecting cerebral ischemia during carotid endarterectomy. Anesthesiology 2007; 107:563-9
59a MURAD MH, SHAHROUR A, SHAH ND, et al. A systematic review and meta-analysis of randomized trials of carotid endarterectomy vs stenting. J Vasc Surg 2011; 53:792-7
60 NALYSNYK L, FAHRBACH K, REYNOLDS MW, ZHAO SZ, ROSS S. Adverse events in coronary artery bypass graft (CABG) trials: a systematic review and analysis. Heart 2003; 89:767-72
61 NASCET: North American Symptomatic Carotid Endarterectomy Trial Collaborators - Beneficial effect of carotid endarterectomy in symptomatic patients with high grade carotid stenosis. N Engl J Med 1991; 325:445-53
62 NAYLOR AR, CUFFE R, TORHWELL PM, et al. A systematic review of outcomes following synchronous carotid endarterectomy and coronary artery bypass: Influence of surgical and patient variables. Eur J Vasc Endovasc Surg 2003; 26:230-41
63 NAYLOR AR, MEHTA Z, ROTHWELL PM, et al. Stroke during coronary artery bypass surgery: A critical review of the role of carotid artery disease. Eur J Vasc Endovasc Surg 2002; 23:283-94
64 NOLLERT G, SHINOKA T, JONAS RA. Near-infrared spectrophotometry of the brain in cardiovascular surgery. J Thorac Cardiovasc Surg 1998; 46:167-75
65 PANDIT JJ, DUTTA D, MORRIS JF. Spread of injectate with superficial cervical plexus block in humans: an anatomical study. Br J Anaesth 2003; 91:733-5
66 PANDIT JJ, SATYA-KRISHNA R, GRATION P. Superficial or deep cervical plexus block for carotid endarterectomy: a systematic review of complications. Br J Anaesth 2007; 99:159-69
66a PENNEKAMP CWA, MOLL FL, De BORST GJ. The potential benefits and the role of cerebral monitoring in carotid endarterectmy. Curr Opin Anaesthesiol 2011; 24:693-7
67 POWERS WJ. Hemodynamics in ischemic cerebrovascular disease. Ann Neurol 1991; 29:231-40
67a RAMACHANDRAN SK, PICTON P, SHANKS A, et al. Comparison of intermediate vs subcutaneous cervical plexus block for caroditd endarterectomy. Br J Anaesth 2011; 107:157-63
68 RAMPIL IJ. A primer for EEG signal processing in anesthesia. Anesthesiology 1998: 89:980-1002
69 RERKASEM K, BOND R, ROTHWELL PM. Local versus general anaesthesia for carotid endarterectomy. Cochrane Database Syst Rev 2004; (2):CD000126
70 RINGELSTEIN EB, DROSTE DW, BABIKIAN VL, et al. Consensus on microembolus detection by TCD. Stroke 1998; 29:725-9
71 RINGLEB PA, ALLENBERG J, BRUCKMANN H, et al. 30 day results from the SPACE trial of stent-protected angioplasty versus carotid endarterectomy in symptomatic patients: a randomized noninferiority trial. Lancet 2006; 368:1239-47
72 ROCKMAN CB, CASTILLO J, ADELMAN MA, et al. Carotid endartectomy in female patients: are the concerns of the asymptomatic carotid atherosclerosis study valid ? J Vasc Surg 2001; 33:236-41
73 ROWED DW, HOULDEN DA, BURKHOLDER LM, TAYLOR AB. Comparison of monitoring techniques for intraoperative cerebral ischemia. Can J Neurol Sci 2004; 31:347-56
74 RUCHAT P. Statistiques concernant les thrombendarterectomies carotidiennes au CHUV. Données non publiées. Décembre 2009
75 SACCO RL, ADAMS R, ALBERS G et al. Guidelines for prevention of stroke in patients with ischemic stroke or transient ischemic attack. Stroke 2006; 37:577-617
76 SCHELLER MS, TODD MM, DRUMMOND JC. Isoflurane, halothane and regional cerebral blood flow at various levels of paCO2 in rabbits.Anesthesiology 1986; 64:598-604
77 SCHWARTZ G, LITSCHER G. Transcranial cerebral oxymetry, transcranial Doppler sonography, and heart rate variability: useful neuromotitoring tools in anaesthesia and intensive care ? Eur J Anaesthesiol 2002; 19:543-9
78 SCOTT DB. Techniques illustrées d’anesthésie loco-régionale. Arnette, Paris 1989, p74-77
79 SEBEL PS, LANG E, RAMPIL IJ, et al. A multicenter study of bispectral electroencephylogram analysis for monitoring anesthetic depth. Anesth Analg 1997; 84:891-9
80 SERAGLIO P, CAMPOSTELLA FA. Cervical plexus block and continuous cervical peridural block with ropivacaine for carotid surgery: a comparison between the two methods. Minerva Anesthesiol 2001; 67:65-70
81 SIEBER FE, TOUNG TJ, DIRINGER MN, et al. Preoperative risks predict neurologic outcome of carotid endarterectomy related stroke. Neurosurgery 1992; 30:847
82 SPACE Collaborative Group. 30-day results from the SPACE trial of stent-protected angioplasty versus carotid endarterectomy in symptomatic patients: a randomised non-inferiority trial. Lancet 2006; 368:1239-47
83 STONEHAM MD, DOYLE AR, KNIGHTON JD, et al. Prospective, randomized comparison of deep or superficial cervical plexus block for carotid endarterectomy surgery. Anesthesiology 1998; 89:907-12
84 STONEHAM MD, THOMPSON JP. Arterial pressure management and carotid endarterectomy. Br J Anaesth 2009; 102:442-52
85 STRINGER WA, HASSO AN, THOMPSON JR, et al. Hyperventilation-induced cerebral ischemia in patients with acute brain lesions: demonstration by Xenon-enhanced CT. Am J Neuroradiol 1993; 14:465-84
86 WATTS K, LIN PH, BUSH RL, et al. The impact of anesthetic modality on the outcome of carotid endarterectomy. Am J Surg 2004; 188:741-7
87 WELSBY IJ, RYAN JM, BOOTH JV, et al. The bispectral index in the diagnosis of perioperative stroke: A case report and discussion. Anesth Analg 2003; 96:435-7
88 WHITELY D, CHERRY KJ. Predictive value of carotid artery stump pressures during carotid endartectomy. Neurosurg Clin N Am 1996; 7:723-32
89 YADAV JS, WHOLEY MH, KUNTZ RE, et al. Protected carotid-artery stenting versus endarterectomy in high-risk patients. N Engl J Med 2004; 351:1493-501
90 YASTREBOV K. Intraoperative management: carotid endarterectomies. Anesthesiol Clin N Am 2004; 22:265-87
91 YOUNG-KUG K, HWANG GS, HUH IY, et al. Altered autonomic cardiovascular regulation after combined deep and superficial cervical plexus blockade for carotid endarterectomy. Anesth Analg 2006; 103:533-9
92 ZEEBREGTS CJ, MEERWALDT R, GEELKERKEN RH. Carotid artery stenting: a 2009 update. Curr Opinion Cardiol 2009; 24:528-31