Cardiogramme
Logo   Accueil | Table des matières | Téléchargements | Liens |   Mentions légales   | Contact |Abréviations
Logo  

Bibliographie


Lectures conseillées

ARORA P, KOLLI H, NAINANI N, et al. Preventable risk factors for acute kidney injury in patients undergoing cardiac surgery. J Cardiothorac Vasc Anesth 2012; 26:687-97
BENHABBOUCHE S, CROLA DA SILVA C, FERRARA AR. Base des phénomènes d’ischémie reperfusion et de la protection myocardique. Ann Fr Anesth Réan 2011; 30:S2-S16
COLEMAN MD, SHAEFI S, SLADEN RN. Preventing acute kidney injury after cardiac surgery. Curr Opin Anesthesiol 2011; 24:70-6
GROGAN K, STEARNS J, HOGUE CW. Brain protection in cardiac surgery. Anesthesiol Clin 2008; 26: 521-38
MENASCHE P. Protection myocardique. In: JANVIER G, LEHOT JJ. Circulation extracorporelle: principes et pratique, 2ème édition. Paris: Arnette Groupe Liaison SA, 2004,157-79

 

Références

1 ABAH U, ROBERTS PG, ISHAQ M, et al. Is cold or warm cardioplegia superior for myocardial protection ? Interact Cardiovasc Thorac Surg 2012 ; 14 :848-55
2 ABU-OMAR Y, BALACUMARASWAMI L, PIGOTT DW, et al. Solid and gazeous cerebral micro-embolization during off-pump, on-pump and open cardiac surgery procedures. J Thorac Cardiovasc Surg 2004; 127:1759-65
3 AFIFI S. Pro: Cerebrospinal fluid drainage protects the spinal cord during thoracoabdominal aortic reconstruction surgery. J Cardiothorac Vasc Anesth 2002; 16:643-9
4 ANGELI E. The crystalloid cardioplegia: advantages with a word of caution. Ann Fr Anesth Réan 2011; 30:S17-S19
5 ANTMAN E, COOPER H, McKINLEY S, et al. Early administration of intravenous magnesium to high-risk patients with acute myocardial infarction in the Magnesium in Coronaries (MAGIC) trial : a randomized controlled trial. Lancet 2002 ; 360 :1189-96
6 ARONSON S, DYKE CM, STIERER KA, et al. The ECLIPSE trials: Comparative studies of clevidipine to nitroglycerin, sodium nitropusside and nicardipine for acute hypertension treatment in cardiac surgery patients. Anesth Analg 2008; 107:1110-21
7 ARORA P, KOLLI H, NAINANI N, et al. Preventable risk factors for acute kidney injury in patients undergoing cardiac surgery. J Cardiothorac Vasc Anesth 2012; 26:687-97
8 ARROWSMITH JE, GROCOTT HP, REVES JG, et al. Central nervous system complications of cardiac surgery. Br J Anaesth 2000; 84:378-93
9 ATAKA K, CHEN D, McCULLY J, et al. Magnesium cardioplegia prevents accumulation of cytosolic calcium in the ischemic myocardium. J Mol Cell Cardiol 1993; 25:1387-90
10 AUGOUSTIDES JGT. The inflammatory response to cardiac surgery with cardiopulmonary bypass : shoud steroid prophylaxis be routine ? J Cardiothorac Vasc Anesth 2012 ; 26 :952-8
11 AZIZZADEH A, HUYNH TT, MILLER CC, SAFI HJ. Reversal of twice-delayed neurologic deficits with cerebrospinal fluid drainage after thoracoabdominal aneurysm repair. A case report and a plea for a national database collection. J Vasc Surg 2000; 31:592-8
12 AZMOON S, DEMAREST C, PUCILLO AL, et al. Neurologic and cardiac benefits of therapeutic hypothermia. Cardiol Rev 2011; 19:108-14
13 BACK MR, BANDYK M, BRADNER M, et al. Critical analysis of outcome determinants affecting repair of intact aneurysms involving the visceral aorta. Ann Vasc Surg 2005; 19:648-56
14 BAIRD TA, PARSONS MV, PHANH T, et al. Persistent poststroke hyperglycemia is independently associated with infarct expansion and worse clinical outcome. Stroke 2003; 34:2208-14
15 BAR-YOSEF S, ANDERS M, MACKENSEN GB, et al. Aortic atheroma burden and cognitive dysfunction after coronary artery bypass graft surgery. Ann Thorac Surg 2004; 78:1556-62
16 BEHNIA R, KOUSHANPOUR E, BRUNNER EA. Effects of hyperosmotic mannitol infusion on hemodynamics of dog kidney. Anesth Analg 1996; 82:902
17 BELLOMO R, CHAPMAN M, FINFER S, et al. Low-dose dopamine in patients with early renal dysfunction: A placebo controlled randomized trial. Lancet 2000; 356:2139-43
18 BENHABBOUCHE S, CROLA DA SILVA C, FERRARA AR. Base des phénomènes d’ischémie reperfusion et de la protection myocardique. Ann Fr Anesth Réan 2011; 30:S2-S16
19 BENJO A, THOMPSON RE, FINE D, et al. Pulse pressure is an age-independent predictor of stroke development after cardiac surgery. Hypertension 2007; 50:630-5
20 BERGMAN AS, ODAR-CEDERLOF I, WESTMAN L, et al. Diltiazem infusion for renal protection in cardiac surgical patients with pre-existing renal dysfunction. J Cardiothorac Vasc Anesth 2002; 16:294-9
21 BIANCARI F, MOSORIN M, RASINAHO E, et al. Postoperative stroke after off-pump versus on-pump coronary artery bypass surgery. J Thorac Cardiovasc Surg 2007; 133:169-73
22 BIGNAMI E, BIONDI-ZOCCAI G, LANDONI G, et al. Volatile anesthetics reduce mortality in cardiac surgery. J Cardiothorac Vasc Anesth 2009; 23:594-9
23 BILLINGS FT, PRETORIUS M, SIEW ED, et al. Early postoperative statin therapy is associated with a lower incidence of acute kidney injury after cardiac surgery. J Cardiothorac Vasc Anesth 2010; 24: 913-20
24 BISSONNETTE B, HOLTBY HM, PUA DAJ, ET AL. Cerebral hyperthermia in children after cardiopulmonary bypass. Anesthesiology 2000; 93:611-8
25 BOLDT J, KING D, SHELD HH, et al. Lung management during cardiopulmonary bypass: Influence on extravascular lung water. J Cardiothorac Vasc Anesth 1990; 4:73-8
26 BORGER MA, RAO V. Temperature management during cardiopulmonary bypass: Effect of rewarming rate on cognitive dysfunction. Semin Cardiothorac Vasc Anesth 2002; 6:17-20
27 BOWLES BJ, LEE JD, DANG CR, et al. Coronary artery bypass performed without the use of cardiopulmonary bypass is associated with reduced cerebral microemboli and improved clinical results. Chest 2001; 119: 25-30
28 BREZIS M, ROSEN S. Hypoxia of the renal medulla – its implications for disease. N Engl J Med 1995; 332:647-55
29 BREYER MD, BREYER RM. Prostaglandin receptors: their role in regulating renal function. Curr Opin Nephrol Hypertens 2000; 9:23-9
30 BROGDEN RN, MARKHAM A. Fenoldopam: a review of its pharmacodynamic and pharmacokinetics properties and intravenous clinical potential in the management of hypertensive urgencies and emergencies. Drugs 1997; 54:634-50
31 BROOKER RF, BROWN WR, MOODY DM, et al. Cardiotomy suction: a major source of brain lipid emboli during cardiopulmonary bypass. Ann Thorac Surg 1998; 65:1651-8
32 BROWN WR, MOODY DM, CHALLA VR, et al. Longer duration of cardiopulmonary bypass is associated with greater numbers of cerebral microemboli. Stroke 2000; 31:707-13
33 BUCKBERG GD. Strategies and logic of cardioplegic delivery to prevent, avoid and reverse ischemic and reperfusion damage. J Thorac Cardiovasc Surg 1987; 93:127-35
34 BUCKBERG GD. Update on current techniques of myocardial protection. Ann Thorac Surg 1995; 60:805-14
35 BURNS K, CHU M, NOVICK RJ. Perioperative N-acetylcysteine to prevent renal dysfunction in high-risk patients undergoing CABG surgery. JAMA 2005; 294:342-50
36 CAIMMI PP, PAGANI L, MICALIZZI E, et al. Fenoldopam for renal protection in patients undergoing cardiopulmonary bypass. J Cardiothorac Vasc Anesth 2003; 17:491-4
37 CALAFIORE AM, TEODORI G, MEZZETTI A, et al. Intermittent antegrade warm blood caredioplegia. Ann Thorac Surg 1995; 59:398-402
38 CALAFIORE AM, DI MAURO M, TEODORI G, et al. Impact of aortic manipulation on incidence of cerebrovascular accidents after surgical myocardial revascularization. Ann Thorac Surg 2002; 73: 1387-93
39 CANTAROVITCH F, RANGOONWALA B, LORENZ H, et al. High-dose furosemide for established ARF: a prospective, randomized, double-blind, placebo-controlled, multicenter trial. Am J Kidney Dis 2004; 44:402-9
40 CAO L, YOUNG N, LIU H, et al. Preoperative aspirin use and outcomes in cardiac surgery patients. Ann Surg 2011; 255:399-404
41 CAPES SE, HUNT D, MALMBERG K, et al. Stress hyperglycemia and prognosis of stroke in nondiabetic and diabetic patients: A systematic overview. Stroke 2001; 32:2426-32
42 CAPPABIANCA G, ROTUNNO C, DE LUCA TUPPUTI L, et al. Protective effects of steroids in cardiac surgery: A meta-analysis of randomized double-blind trials. J Cardiothorac Vasc Anesth 2011; 25:156-65
43 CARCOANA OV, MATHEW JP, DAVIS E, et al. Mannitol and dopamine in patients undergoing cardiopulmonary bypass: a randomized clinical trial. Anesth Analg 2003; 97:1222-9
44 CASON BA, GAMPERL AK, SLOCUM RE, HICKEY RF. Anesthetic-induced preconditioning: previous administration of isoflurane decreases myocardial infarct size in rabbits. Anesthesiology 1997; 87: 1182-90
45 CHAMBERS DJ, SAKAI A, BRAIMBRIDGE MV, et al. Clinical validation of St. Thomas’s Hospital cardioplegic solution No. 2 (Plegisol). Eur J Cardiothorac Surg 1989; 3:346-52
46 CHERTOW GM, BURDICK E, HONOUR M, et al. Acute kidney injury, mortality, length of stay, and costs in hospitalized patients. J Am Soc Nephrol 2005; 16:3365-70
47 CHERTOW GM, SAYEGH MH, ALLGREN RL, et al. Is the administration of dopamine associated with adverse or favourable outcomes in acute renal failure ? Am J Med 1996; 101:49-53
48 CHINNAN NK, PURI GD, THINGMAN SKS. Myocardial protection by nicorandil during open-heart surgery under cardiopulmonary bypass. Eur J Anaesthesiol 2006; 24
49 CHENG DC, BAINBRIDGE D, MARTIN JE, NOVICK RJ. Does off-pump coronary artery bypass reduce mortality, morbidity, and resource utilization when compared with conventional coronary artery bypass? A meta-analysis of randomized trials. Anesthesiology 2005; 102:188-203
50 CINA CS, ABOUZAHR L, ARENA GO, et al. Cerebrospinal fluid drainage to prevent paraplegia during thoracic and thoracoabdominal aortic aneurysm: A systematic review and meta-analysis. J Vasc Surg 2004; 40:36-44
51 COLEMAN MD, SHAEFI S, SLADEN RN. Preventing acute kidney injury after cardiac surgery. Curr Opin Anesthesiol 2011; 24:70-6
52 CONLON P, STAFFORD-SMITH M, WHITE W, et al. Acute renal failure following surgery. Nephrol Dial Transplant 1999; 14:1158-62
53 CONZEN PF, FISCHER S, DETTER C, PETER K. Sevoflurane provides greater protection of the myocardium than propofol in patients undergoing off-pump coronary artery bypass surgery. Anesthesiology 2003; 99:826-33
54 COOK DJ. Neurologic effects. In: GRAVLEE GP (ed). Cardiopulmonary bypass. 2nd edition. Philadelphia, Lippincott, Williams & Wilkins, 2000, pp 403-31
55 COSELLI JS, LEMAIRE SA, KOKSOY C, et al. Cerebrospinal fluid drainage reduces paraplegia after thoracoabdominal aortic aneurysm repair: results of a randomized clinical trial. J Vasc Surg 2002; 35:631-9
56 CRAWFORD ES, SVENSSON LG, HESS KR, et al. A prospective randomized study of cerebrospinaél fluid drainage to prevent paraplegia after high-risk surgery of the thoracoabdominal aorta. J Vasc Surg 1991; 13:36-46
57 CROUGHWELL ND, NEWMAN NF, BLUMENTHAL JA, et al. Jugular bulb saturation and cognitive dysfunction after cardiopulmonary bypass. Ann Thorac Surg 1994; 58:1702-8
58 DAVILA-ROMAN VG, BARZILAI B, WAREING TH, et al. Atherosclerosis of the ascending aorta. Stroke 1994; 25:2010-16
59 DAVILA-ROMAN VG, BARZILAI B, WAREING TH, et al. Intraoperative ultrasonographic evaluation of the ascending aorta in 100 consecutive patients undergoing cardiac surgery. Circulation 1991; 84(Suppl III):47-53
60 DECOENE C. La cardioplégie sanguine: avantages et inconvéniuents. Ann Fr Anesth Réan 2011; 30:S20-S22
61 DE FOE GR, ROSS CS, OLMSTEAD EM, et al. Lowest hematocrit on bypass and adverse outcomes associated with coronary artery bypass grafting. Ann Thorac Surg 2001; 71:769-76
62 DE HERT SG. Cardioprotection with volatile anesthetics: clinical relevance. Curr Opin Anesthesiol 2004; 17:57-62
63 DE HERT SG, BROECKE PW, MERTENS E, et al. Sevoflurane but not propofol preserves myocardial function in coronary artery patients. Anesthesiology 2002; 97: 42-9
64 DE HERT SG, CROMHEECKE S, TEN BROECKE PW, et al. Effects of propofol, desflurane and sevoflurane on recovery of myocardial function after coronory surgery in elderly high-risk patients. Anesthesiology 2003; 99:314-23
65 DE HERT SG, LONGROIS D, YANG H, et al. Does the use of a volatile anesthetic regimen attenuate the incidence of cardiac events after vascular surgery ? Acta Anaesthesiol Belg 2008; 59:19-25
66 DE HERT SG, TURANI F, MATHUR S, STOWE DF. Cardioprotection with volatile anesthetics: mechanisms and clinical implications. Anesth Analg 2005; 100:1584-95
67 DE HERT S, VAN DER LINDEN PJ, CROMHEECKE S, et al. Choice of primary anesthetic regimen can influence intensive care unit length of stay after coronary surgery with cardiopulmonary bypass. Anesthesiology 2004; 101:9-20
68 DE HERT S, VAN DER LINDEN PJ, CROMHEECKE S, et al. Cardioprotective properties of sevoflurane in patients undergoing coronary surgery with cardiopulmonary bypass are related to the modalities of its administration. Anesthesiology 2004; 101:299-310
69 Demaria RG, Carrier M, Fortier S, et al. Reduced mortality and strokes with off-pump artery bypass grafting surgery in octogenarians. Circulation 2002; 106(suppl I):I-5-10
70 DE MORAES LOBO EM, BURDMANN EA, ABDULKADER RC. Renal function changes after elective cardiac surgery with cardiopulmonary bypass. Ren Fail 2000; 22:487-97
71 DEXTER F, HINDMAN BJ. Computer simulation of microscopic cerebral air emboli absorption during cardiac surgery. Undersea Hyperb Med 1998; 25:43-50
72 DIAZ GC, MOITRA V, SLADEN RN. Hepatic and renal protection during cardiac surgery. Anesthesiol Clin 2008; 26:565-90
73 DJAIANI G, FEDORKO L, BORGER MA, et al. Continuous-flow CellSaver reduces cognitive decline in elderly patients after coronary bypass surgery. Circulation 2007; 116:1888-95
74 DJINDJIAN R. Arteriography of the spinal cord. Am J Roentgenol 1969; 107:461
75 DRENGER B, PARKER SD, FRANK SM, BEATTIE C. Changes in cerebrospinal fluid pressure and lactate concentration during thoracoabdominal aortic aneuvrysm surgery. Anesthesiology 1997; 86 : 41-7
76 DRUMMOND JD. Do barbiturate really protect the brain? Anesthesiology 1993; 78:611-3
77 DYHR T, NYGARD E, LAURSEN N, et al. Both lung recruitment maneuver and PEEP are needed to increase oxygenation and lung volume after cardiac surgery. Acta Anaesthesiol Scand 2004; 48:187-97
78 EL AZAAB SR, ROSSEEL PM, DE LANGE JJ, et al. Effect of sevoflurane on the ex vivo secretion of TNF-alpha during and after coronary artery bypass surgery. Eur J Anaesthesiol 2003; 20:380-4
79 ENGELMAN DT, WATANABE M, ENGELMAN RM, et al. Constitutive nitric oxide release is impaired after ischemia and reperfusion. J Thorac Cardiovasc Surg 1995; 110:1047-53
80 ESTRERA AL, SHEINBAUM R, MILLER CC, et al. Cerebrospinal fluid drainage during thoracic aortic repair: safety and current management. Ann Thorac Surg 2009; 88:9-15
81 FAN Y, ZHANG AM, XIAO Y, et al. Warm versus cold cardioplegia for heart surgery: a meta-analysis. Eur J Cardiothorac Surg 2010; 37:912-9
82 FEDOROW CA, MOON MC, MUTCH AC, GROCOTT HP. Lumbar cerebrospinal fluid drainage for thoracoabdominal aortic surgery: Rationale and practical considerations for management. Anesth Analg 2010; 111:46-58
83 FOLLETTE DM, MULDER DG, MALONEY JV, et al. Advantages of blood cardioplegia over continuous coronary perfusion or intermittent ischemia. J Thorac Cardiovasc Surg 1978; 76:604-19
84 FORLANI S, TOMAI F, De PAULIS R, et al. Preoperative shift from glibenclamide to insulin is cardioprotective in diabetic patients undergoing coronary artery bypass surgery. J Cardiovasc Surg 2004; 45:117-22
85 FRÄSSDORF J, DE HERT S, SCHLACK W. Anaesthesia and myocardial ischaemia/reperfusion injury. Br J Anaesth 2009; 103:89-98
86 GARWOOD S. Cardiac surgery-associated acute renal injury: New paradigms and innovative therapies. J Cardiothorac Vasc Anesth 2010; 24:990-1001
87 GHARAGOZLOO F, NEVILLE RF, COS JL. Spinal cord protection during surgical procedures on the descending thoracic and thoracoabdominal aorta: A critical overview. Sem Thorac Cardiovasc Surg 1998; 10:73-86
88 GLOVICZKI P, BOWER TC. Visceral and spinal cord protection during thoracoabdominal aortic reconstructions. Semin Vasc Surg 1992; 5(3):163-9
89 GOLD JP, CHARLESON MD, WILLIAMS-RUSSO P, et al. Improvement in outcomes after CABG. A randomized trial comparing intraoperative high versus mean arterial pressure. J Thorac Cardiovasc Surg 1995; 110:1305-14
90 GOLDMAN S, SUTTER F, FERDINAND F, et al. Optimizing intraoperative cerebral oxygen delivery using non-invasive cerebral oxymetry decreases the incidence of stroke for cardiac surgical patients. Heart Surg Forum 2004; 7:E376-80
91 GOODFRIEND TL, ELLIOTT ME, CATT KJ. Angiotensin receptors and their antagonists. N Engl J Med 1996; 334:1649-54
92 GOTO T, BABA T, HOMMA K, et al. Magnetic resonance imaging findings and postoperative neurologic dysfunction in elderly patients undergoing coronary artery bypass grafting. Ann Thorac Surg 2001; 72:137-42
93 GRAVLEE GP, DAVIS RF, KURUSZ M, UTLEY JR. Cardiopulmonary bypass. Principles and practice. Philadelphia: Lippincott Williams & Wilkins, 2000, p 70
94 GRIGORE AM, MURRAY CF, RAMAKRISHNA H, DJAIANI G. A core review of temperature regimens and neuroprotection during cardiopulmonary bypass: does rewarmning rate matter ? Anesth Analg 2009; 109:1741-51
95 GROCOTT HP, ANDREIW A. Con: Topical head cooling should not be used during deep hypothermic circulatory arrest. J Cardiothorac Vasc Anesth 2012; 26:337-9
96 GROCOTT HP, HOMI HM, PUSKAS F. Cognitive dysfunction after cardiac surgery: revisiting etiology. Semin Cardiothorac vasc Anesth 2005; 9:123-9
97 GROCOTT HP, MACKENSEN B, GRIGORE AM, et al. Postoperative hyperthermia is associated with cognitive dysfunction after coronary artery bypass graft surgery. Stroke 2002; 33:537-41
98 GROGAN K, STEARNS J, HOGUE CW. Brain protection in cardiac surgery. Anesthesiol Clin 2008; 26: 521-38
99 GUARRACINO F, LANDONI G, TRITAPEPE L, et al. Myocardial damage prevented by volatile anaesthetics: A multicenter randomized controlled study. J Cardiothorac Vasc Anesth 2006; 20:477-83
100 HAASE M, HAASE-FIELITZ A, BELLOMO R, et al. Sodium bicarbonate to prevent increases in serum creatinine after cardiac surgery: a pilot double-blind, randomized controlled trial. Crit Care Med 2009; 37:39-47
101 HAGL C, ERGIN MA, GALLA JD, et al. Neurologic outcome after ascenting aorta – aortic arch operations: effect of brain protection technique in high-risk patients. J Thorac Cardiovasc Surg 2001; 121:1107-21
102 HARTMAN GS, YAO FSF, BRUEFACH M, et al. Severity of aortic atheromatous disease diagnosed by transesophageal echocardiography predicts stroke and other outcomes associated with coronary artery surgery: a prospective study. Anesth Analg 1996; 83:701-8
103 HAYASHIDA N, SHOUJIMA T, TESHIMA H, et al. Clinical outcomes after cardiac operations in patients with cirrhosis. Ann Thorac Surg 2004; 77:500-5
104 HEMMILA MR, ZELENOCK GB, D’ALECY LG. Post-ischemic hyperglycemia worsens neurologic outcome after spinal chord ischemia. J Vasc Surg 1993; 17:661-8
105 HIRATZKA LF, BAKRIS GL, BECKMAN JA, et al. 2010 ACCF/AHA/AATS/ACR/ ASA/SCA/SCAI/SIR/STS/ SVM Guidelines for the diagnosis and management of patients with thoracic aortic disease: Executive summary. Circulation 2010:121:1544-79
106 HNATH JC, MEHTA M, TAGGERT JB, et al. Strategies to improve spinal cord ischemia in endovascular thoracic aortic repair: outcomes of a prospective cerebrospinal fluid drainage protocol. J Vasc Surg 2008; 48:836-40
107 HO PM, ARCINIEGAS DB, GRIGSBY J, et al. Predictors of cognitive decline following coronary artery bypass graft surgery. Ann Thorac Surg 2004; 77:597-603
108 HOGUE CW, BARZILAI B, PIEPER KS, et al. Sex differences in neurological outcomes and mortality after cardiac surgery: a society of thoracic surgery national data base report. Circulation 2001; 103:2133-7
109 HOGUE CW, PALIN CA, ARROWSMITH JE. Cardiopulmonary bypass management and neuroplogic outcomes: An evidence-based appraisal of current practices. Anesth Analg 2006; 103:21-37
110 HYNNINEN MS, NIEMI TT, PÖYHIÄ R, et al. N-acetylcysteine for the prevention of kidney injury in abdominal aortic surgry: A randomized, double-blind, placebo-controlled trial. Anesth Analg 2006; 102:1638-45
111 JENKINS M, GOLDSMITH D. Statins and kidney disease: is the study of heart and renal protection at the cutting edge of evidence ? Curr Opin Cardiol 2012; 27:429-40
112 JONAS RA. Hypothermia, circulatory arrest, and the pediatric brain. J Cardiothorac vasc Anesth 1996; 10:66-74
113 JONAS RA, WYPIJ D, ROTH SJ, et al. The influence of hemodilution on outcome after hypothermic cardiopulmonary bypass: results of a randomized trial in infants. J Thorac Cardiovasc Surg 2003; 126:1765-74
114 JONES DR, BELLOMO R. Renal-dose dopamine: from hypothesis to paradigm to dogma to myth, and finally, superstition ? Intensive Care Med 2005; 20:199-211
115 JONES DR, LEE HT. Protecting the kidney during critical illness. Curr Opin Anesthesiol 2007; 20:106-12
116 JONES DR, LEE HT. Perioperative renal protection. Best Pract Res Clin Anaesthesiol 2008; 22:193-208
117 JONES T, ROY RC. Should patients be normothermic in the immediate postoperative period ? Ann Thorac Surg 1999; 68:1454-5
118 JOSE PA, EISNER GM, FELDER RA. Role of dopamine receptors in the kidney in the regulation of blood pressure. Curr Opin Nephrol Hypertens 2002; 11:87-92
119 JULIER K, DA SILVA R, GARCIA C, et al. Preconditioning by sevoflurane decreases biochemical markers for myocardial and renal dysfunction in coronary artery bypass graft surgery. Anesthesiology 2003; 98:1315-27
120 KANEKO T, SAITO Y, HIKAWA Y, et al. Dose-dependent prophylactic effect of nicorandil, an ATP-sensitive potassium channel opener, on intra-operative myocardial ischaemia in patients undergoing major abdominal surgery. Br J Anaesth 2001; 86:332-7
121 KARKOUTI K, DJAIANI G, BORGER MA; et al. Low hematocrit during cardiopulmonary bypass is associated with increased risk of perioperative stroke in cardiac surgery. Ann Thorac Surg 2005; 80:1381-7
122 KARKOUTI K, WIJEYSUNDERA DN, YAU TM, et al. Acute kidney injury after cardiac surgery. Focus on modifiable risk factors. Circulation 2009; 119:495-502
123 KARKOUTI K, WIJEYSUNDERA DN, YAU TM, et al. Influence of erythrocyte transfusion on the risk of acute kidney injury after cardiac surgery differs in anemic and non-anemic patients. Anesthesiology 2011; 115:523-30
124 KEHL F, KROLIKOWSKI JG, MRAOVIC B, et al. Is isoflurane-induced preconditioning dose related? Anesthesiology 2002; 96: 675-80
125 KEHL F, KROLIKOWSKI JG, MRAOVIC B, et al. Hyperglycemia prevents isoflurane-induced preconditioning against myocardial infarction. Anesthesiology 2002 ; 96 :183-8
126 KERENDI F, KIN H, HALKOS ME, et al. Remote postconditioning : brief renal ischemia and reperfusion applied before coronary artery reperfusion reduces myocardial infarct size via endogenous activation of adenosine receptors. Basic Res Cardiol 2005 ; 100 :404-12
127 KERN FH, GIESER WG, FARRELL DM. Extracorporeal circulation and circulatory assist devices in the pediatric patient. In: Lake CL. Pediatric cardiac anesthesia, 2nd edition. Norwalk : Appleton & Lange, 1993, pp 151-79
128 KERN FH, UNGERLEIDER RM, REVES JG, et al. The effect of altering pump flow rate on cerebral blood flow and cerebral metabolism in neonates, infants and children. Ann Thorac Surg 1993a; 58:1366-72
129 KEVIN LG, NOVALIJA E, STOWE DF. Reactive oxygen species as mediators of cardiac injury and protection: the relevance to anesthesia practice. Anesth Analg 2005; 101:1275-87
130 KIRKLIN JW, BARRAT-BOYES BG. Cardiac Surgery, 2nd edition, New-York: Churchill-Livingstone 1993, p 74
131 KOUCHOUKOS NT, WAREING TH, IZUMOTO H, et al. Elective hypothermia and cardiopulmonary bypass and circulatory arrest for spinal cord protection during operations on the thoracoabdominal aorta. J Thorac Cardiovasc Surg 1990; 99:659-64
132 LAM CR, GEOGHEGAN T, LEPORE A. Induced cardiac arrest for intracardiac surgical procedures: An experimental study. J Thorac Surg 1955; 30:620-5
133 LAMEIRE N, VAN BIESEN, VANHOLDER R. Acute renal failure. Lancet 2005; 365:417-30
134 LANDONI G, BIONDI-ZOCCAI GGL, TOMLIN JA, et al. Beneficial impact of fenoldopam in critically ill patients with or at risk of acute renal failure: a meta-analysis of randomized clinical trials. Am J Kidney Dis 2007; 49:56-68
135 LANDONI G, BIONDI-ZOCCAI GGL, ZANGRILLO A, et al. Desflurane and sevoflurane in cardiac surgery: A meta-analysis of randomized clinical rials. J Cardiothorac Vasc Anesth 2007; 21:502-11
136 LASSNIGG A, DONNER E, GRUBHOFER G, et al. Lack of renoprotective effects od dopamine and furosemide during cardiac surgery. J Am Soc Nephrol 2000; 11:97-104
137 LASSNIGG A, SCHMIDLIN D, MOUHIEDDINE M, et al. Minimal changes of serum creatinine predict prognosis in patients after cardiothoracic surgery : a prospective cohort study. J Am Soc Nephrol 2004 ; 15 :1597-605
138 LEE HT, MIHWA K, JAN M, et al. Antiinflammatory and antinecrotic effects of the volatile anesthetic sevoflurane in kidney proximal tubule celles. Am J Physiol Renal Physiol 2006 ; 291 :F67-78
139 LEGAULT C, FURBERG CD, WAGENKNECHT LE, et al. Nimodipine neuroprotection in cardiac valve replacement : report of an early terminated trial. Stroke 1996 ; 27 :593-8
140 LEWIS J, SALEM MM, CHERTOW GM, et al. Atrial natriuretic factor in oliguric acute renal failure. Auriculin Anaritide Acute Renal Failure Study Group. Am J Kidney Dis 2000; 36:767-74
141 LIAKOPOULOS OJ, CHOI YH, HALDENWANG PL, et al. Impact of preoperative statin therapy on adverse postoperative outcomes in patients undergoing cardiac surgery: A meta-analysis of over 30,000 patients. Eur Heart J 2008; 29:1548:59
142 LING E, ARELLANO R. Systematic overview of the evidence supporting the use of cerebrospinal fluid drainage in thoracoabdominal aneuvrysm surgery for prevention of paraplegia. Anesthesiology 2000; 93:1115-22
143 LIU YH, WANG DX, LI LH, et al. The effects of cardiopulmonary bypass on the number of cerebral microemboli and the incidence of cognitive dysfunction after coronary artery bypass graft surgery. Anesth Analg 2009; 109:1013-22
144 LOZANO S, MOSSAD E. Cerebral function monitors during pediatric cardiac surgery: can they make a difference ? J Cardiothorac Vasc Anesth 2004; 18:645-56
145 LUDWIG LM, PATEL HH, GROSS GJ, et al. Morphine enhances pharmacological preconditioning by isoflurane. Anesthesiology 2003; 98:705-11
146 LUND C, HOL PK, LUNDBLAD R, et al. Comparison of cerebral embolization during off-pump and on-pump coronary artery bypass surgery. Ann Thorac Surg 2003; 76:765-70
147 MALLIDI HR, SEVER J, TAMARIZ M, et al. The short-term and long-term effects of warm or tepid cardioplegia. J Thorac Cardiovasc Surg 2003; 125:711-20
148 MARASCO SF, SHARWOOD LN, ABRAMSON MJ. No improvement in neurocognitive outcomes after off-pump versus on-pump coronary revascularisation: A meta-analysis. Eur J Cardiothorac Surg 2008; 33:961-70
149 MARIK PE. Low-dose dopamine: a systematic review. Intens Care Med 2002; 28:877-83
150 MARINI CP, LEVISON J, CALIENDO F, NATHAN IM, COHEN JR. Control of proximal hypertension during aortic cross-clamping: Its effect on cerebrospinal fluid dynamics and spinal cord perfusion pressure. Sem Cardiovasc Surg 1998; 10:51-6
151 MAZZARELLA V., TACCONE G.M., TOZZI C., et al. Renal functions in patients undergoing cardiopulmonary bypass operations. J Thorac Cardiovasc Surg 1992; 104:1625-7
152 MEHLHORN U, ALLEN SJ, ADAMS DL, et al. Cardiac surgical conditions induced by b-blockade: effect on myocardial fluid balance. Ann Thorac Surg 1996; 62:143-50
153 MEHTA RL, KELLUM JA, SHAH SV, et al. Acute Kidney Injury Network : report of an initiative to improve outcomes in acute kidney injury. Crit Care 2007 ; 11 : R31
154 MEHTA SR, YUSUF S DIAZ R, et al. Effect of glucose-insulin-potassium infusion on mortality in patients with acute ST-segment elevation myocardial infarction : the CREATE-ECLA randomized controlled trial. JAMA 2005 ; 293 :437-46
155 MELROSE DG, DREYER B, BENTALL HH, et al. Elective cardiac arrest. Lancet 1955; 2:21-2
156 MENTZER RM, BATTELS C, BOLLI R, et al. Sodium-hydrogen exchange inhibition by cariporide to reduce the risk of ischemic cardiac events in patients undergoing coronary artery bypass grafting: results of the EXPEDITION study. Ann Thorac Surg 2008; 85:261-70
157 MENTZER RM, OZ MC, SLADEN RN, et al. Effects of perioperative nesiritide in patients with left ventricular dysfunction undergoing cardiac surgery: the NAPA Trial. J Am Coll Cardiol 2007; 49:716-26
158 MINGUET G, JORIS J, LAMY M. Preconditioning and protection against ischaemia-reperfusion in non-cardiac organs : a place for volatile anaesthetics ? Eur J Anaesthesiol 2007 ; 24 :733-45
159 MITCHENFELDER JD. The awake brain. In: Anesthesia and the brain. New-York: Churchill-Livingstone, 1988, 7-8
160 MITCHENFELDER JD, MILDE JH. The relationship among canine brain temperature, metabolism and function during hypothermia. Anesthesiology 1991; 75:130-6
161 MORELLI A, ZACCARIA R, BELLOMO R, et al. Prophylactic fenoldopam for renal protection in sepsis : a randomized, double-béind, placebo-controlled pilot trial. Crit Care Med 2005 ; 33 :2451-6
162 MUIR JA, LEES KR, FORD I, et al. Magnesium for acute stroke (Intravenous Magnesium Efficacy in Stroke Trial) : randomized controlled trial. Lancet 2004 ; 363 : 439-45
163 MULLENHEIM J, FRAGDORF J, PRECKEL M, et al. Ketamine, but not S(+)-ketamine, blocks ischemic preconditioning in rabbitt hearts in vivo. Anesthesiology 2001; 94:630-6
164 MURKIN JM. Adverse central nervous system outcomes after cardiopulmonary bypass. A beneficial effect of aprotinin ? Semin Cardiothorac Vasc Anesth 2001; 5:282-5
165 MURKIN JM. Neurocognitive outcomes: the year in review. Curr Opin Anesthesiol 2005; 18:57-62
166 MURKIN JM, MARTZKE JS, BUCHAN AM, et al. A randomized study of the iunfluence of perfusion technique and pH management strategy in 316 patients undergoing coronary artery bypass surgery. II Neurologic and cognitive outcomes. J Cardiothorac Vasc Surg 1995; 110:349-55
167 MURRY CE, JENNINGS RB, REIMER KA. Preconditionning with ischemia: A delay of lethal cell injury in ischemic myocardium. Circulation 1986; 74:1124-36
168 MYLES PS, HUNT JO, HOLDGAARD HO, et al. Clonidine and cardiac surgery: Haemodynamic and metabolic effects, myocardial ischaemia and recovery. Anaesth Intensive Care 1999; 27:137-47
169 NEUMAYER HH, KUNZENDORF U, SCHREIBER M. Protective effects of calcium antagonists in human renal transplantation. Kidney Internat 1992; 36(S):S87-S93
170 NGUYEN L, BANKS D, MADANI M, et al. Anesthetic implications of partial left-heart bypass for repair of the descending thoracic aorta. J Cardiothorac Vasc Anesth 2009; 23:893-900
171 NIGWEKAR SU, KANDULA P, HIX JK, et al. Off-pump coronary artery bypass surgery and acute kidney injury : A meta-analysis of randomized and observational studies. Am J Kidney Dis 2009 ; 54 : 413-23
172 NOVALIJA E, VARADARAJAN SG, CAMARA AKS, et al. Anesthetic preconditioning : triggering role of reactive oxygen and nitrogen species in isolated hearts. Am J Physiol Heart Circ Physiol 2002 ; 283 :H44-52
173 NUGENT M. Pro: Cerebrospinal fluid drainage prevents paraplegia. J Cardiothorac Vascul Anesth 1992; 3:366-8
174 NUSSMEIER NA, ARLUNG C, SLOGOFF S. Neuropsychological dysfunction after cardio-pulmonary bypass: cerebral protection by a barbiturate. J Cardiothorac Vasc Anesth 1991; 5:584-9
175 NUSSMEIER NA, CHENG W, MARINO M, et al. Temperature during cardiopulmonary bypass: The discrepancies between monitoring sites. Anesth Analg 2006; 103:1373-9
176 O’DWYER C, WOODSON LC, CONROY BP. Regional perfusion abnormalities with phenylephrine during normothermic bypass. Ann Thorac Surg 1997; 63:728-35
177 PASCOE EA, HUDSON RJ, ANDERSON BA, et al. High-dose thiopentone for open-chamber cardiac surgery : a retrospective review. Can J Anaesth 1996 ; 43 :575-9
178 PATEL BM, CHITTOK DR, RUSSEL JA, WALLEY KR. Beneficial effects of short-term vasopressin infusion during severe septic shock. Anesthesiology 2003; 96:576-82
179 PATEL RL, TURTLE MR, CHAMBERS DJ, et al. Alpha-stat acid-base regulation during cardiopulmonary bypass improves neuropsychologic outcomes in patients udergoing coronary artery bypass grapfting. J Thorac Cardiovasc Surg 1996; 111:1267-79
180 PETERS CE, KORCOK J, GELB AW, et al. Anesthesthetic concentrations of propofol protect against oxydative stress in primary astrocyte cultures: comparison with hypothermia. Anesthesiology 2001; 94:313-21
181 PICKER O, BECK C, PANNEN B. Liver protection in the perioperative setting. Best Pract Res Clin Anaesthesiol 2008 ; 22 : 209-24
182 PRATT PF, WANG C, WEIHRAUCH D, et al. Cardioprotection by volatile anesthetics: new applications for old drugs ? Curr Opin Anesthesiol 2006; 19:397-403
183 RAJA SG, DREYFUS GD. Off-pump coronary artery bypass surgery: To do or not to do? Current best available evidence. J Cardiothorac Vasc Anesth 2004; 18:486-505
184 RANUCCI M, DE BENEDETTI D, BIANCHINI C, et al. Effects of fenoldopam infusion in complex cardiac surgical operations: a prospective, randomised, double-blind, placebo-controlled study. Minerva Anesthesiol 2010; 76:249-59
185 REEVES ST, GLAS KE, ELTZSCHIG H, et al. Guidelines for performing a comprehensive epicardial echocardiographic examination: Recommendations of the American Society of Echocardiography and the Society of Cardiovascular Anesthesiologists. J Am Soc Echocardiogr 2007; 20:427-37
186 REID RW, WARNER DS. Pro: Arguments for use of barbiturates in infants and children undergoing deep hypothermic circulatory arrest. J Cardiothorac Vasc Anesth 1998; 12:591-4
187 RINNE TT. Cardioprotection and cardioplegia. In: THYS DM, et al, eds. Textbook of cardiothoracic anesthesiology. New York, McGraw-Hill Co, 2001, 488-511
188 ROACH GW, KANCHUGER M, MORA MANGANO C, et al. Adverse cerebral outcomes after coronary bypass surgery. N Engl J Med 1996; 335:1857-64
189 ROSENKRANZ ER. Myocardial preservation. In: ESTEFANOUS F, et al, Eds. Cardiac anesthesia. principles and clinical practice. Philadelphia, Lippincott Williams & Wilkins, 2001, 387-414
190 RUNG GW, WICKEY GS, MYERS JL, et al. Thiopental as an adjunct to hypothermia for EEG suppression in infants prior to circulatory arrest.. J Cardiothorac Vasc Anesth 1991; 5:337-42
191 RYAN T, MANNION D, O’BRIEN W, et al. Spinal cord perfusion pressure in dogs after control of proximal aortic hypertension during thoracic aortic cross-clamping wirh esmolo or sodium nitroprusside. Anesthesiology 1993; 8:317-22
192 SAFI HJ, MILLER CC, HUYNH TT, ET AL. Distal aortic perfusion and cerebrospinal fluid drainage for thoracoabdominal and descending tjoracic aortic repair: ten years of organ protection. Ann Surg 2003; 238:372-80
193 SAGAR UN, KANDULA P. N-acetylcysteine in cardiovascular surgery-associated renal failure: A meta-analysis. Ann Thorac Surg 2009; 87:139-47
194 SAITO S, MIZUMURA T, TAKAYAMA T, et al. Antiischemic effects of nicorandil during coronary angioplasty in humans. Cardiovasc Drug Ther 1995; 9(suppl 2):257-63
195 SALAZAR JD, WITYK RJ, GREGA MA, et al. Stroke after cardiac surgery: short- and long-term outcomes. Ann Thorac Surg 2001; 72:1195-201
196 SCHOENWALD PK. Intraoperative management of renal function in the surgical patient at risk. Anesthesiol Clin N Am 2000; 18:719-37
197 SELNES OA, GOTTESMAN RF, GREGA MA, et al. Cognitive and neurologic outcomes after coronary artery bypass surgery. N Engl J Med 2012; 366:250-7
198 SHARONY R, BIZEKIS CS, KANCHUGER M, et al. Off-pump coronary artery bypass grafting reduces mortality and stroke in patients with atheromatous aortas: A case control study. Circulation 2003; 108 (suppl II):15-20
199 SHENAQ SA. Anesthesia for thoracic aortic aneurysms. Curr Opinions Anaesthesiol 1992; 5:62-7
200 SHENAQ SA, SVENSSON LG. Con: Cerebrospinal fluid drainage does not afford spinal cord protection during resection of thoracic aneurysms. J Cardiothorac Vascul Anesth 1992; 3:369-72
201 SHENAQ SA, SVENSSON LG. Paraplegia following aortic surgery. J Cardiothorac Vascul Anesth 1993; 7:81-94
202 SHROYER AL, COOMBS LP, PETERSON ED, et al. The Society of Thoracic Surgeons: 30-day operative mortality and morbidity risk models. Ann Thorac Surg 2003; 75:1856-64
203 SHUM-TIM D, TCHERVENKOV CI, JUMAL AM, et al. Systemic steroid pretreatment improves cerebral protection after circulatory arrest. Ann Thorac Surg 2001; 72:1465-71
204 SHUMWAY NE, LOWER RR. Topical cardiac hypothermia for extended periods of anoxic cardiac arrest. Surg Forum 1960; 10:563
205 SIGG DC, COLES JA, GALLAGHER WJ, et al. Opioid preconditioning: Myocardial function and energy metabolism. Ann Thorac Surg 2001; 72:1576-82
206 SINHA A, CHEUNG AT. Spinal cord protection and thoracic aortic surgery. Curr Opin Anaesthesiol 2010; 23:95-102
207 SLATER JP, GUARINO T, STACK J, et al. Cerebral oxygen desaturation predicts cognitive decline and longer hospital stay after cardiac surgery. Ann Thorac Surg 2009; 87:36-44
208 SLINGER P. Perioperative lung injury. Best Pract Res Clin Anaesthesiol 2008; 22: 177-91
209 SNIECINSKI R, LIU H. Reduced efficacy of volatile anesthetic presconditioning with advanced age in isolated rat myocardium. Anesthesiology 2004; 100:589-97
209a STAHL GL, SHERMAN SK, SMITH PK, LEVY JH. Complement activation and cardiac surgery : a novel target for improving outcomes. Anesth Analg 2012 ; 115 :759-71
210 Stallwood MI, Grayson AD, Mills K, Scawn ND. Acute renal failure in coronary artery bypass surgery: independant effect of cardiopulmonary bypass. Ann Thorac Surg 2004; 77:968-72
211 STONE GW, McCULLOUGH PA, TUMLIN JA, et al. Fenoldopam mesylate for the prevention of contrast-induced nephropathy: a randomized controlled trial. JAMA 2003; 290:2284-91
212 STAFFORD-SMITH M. Evidence-based renal protection in cardiac surgery. Semin Cardiothorac Vasc Anesth 2005; 90:65-76
213 STUB D, BERNARD S, DUFFY SJ, et al. Post cardiac arrest syndrome. A review of therapeutic strategies. Circulation 2011; 123:1428-35
214 STUMP DA, JONES TJJ, RORIE KD. Neurophysiologic monitoring and outcomes in cardiovascular surgery. J Cardiothorac Vasc Anesth 1999; 13:600-13
215 STURGESS J, MATTA B. Brain protection: current and future options. Best Pract Res Clin Anaesthesiol 2008; 22:167-76
216 SUNGURTEKIN H, COOK DJ, ORSZULAK TA, et al. Cerebral response to hemodilution during hypothermic cardiopulmonary bypass in adults. Anesth Analg 1999; 89:1078-83
217 SUNGURTEKIN H, BOSTON US, COOK DJ. Bypass flow, mean arterial pressure, and cerebral perfusion during cardiopulmonary bypass in dogs. J Cardiothorac Vasc Anesth 2000; 14:25-8
218 SVENSSON LG, CRAWFORD ES, HESS KR, et al. Experience with 1509 patients undergoing thoracoabdominal aortic operations. J Vasc Surg 1993; 17:357-70
219 SVENSSON LG, HESS KR, D’AGOSTINO RS, et al. Reduction of neurologic injury after high-risk thoracoabdominal aortic operation. Ann Thorac Surg 1998; 132-8
220 SVYATETS M, TOLANI K, ZHANG M, et al. Perioperative management of deep hypothermic circulatory arrest. J Cardiothorac Vasc Anesth 2010; 24:644-65
221 SWAMINATHAN M, PHILIPS-BUTE BG, CONLON PJ, et al. The association of lowest hematocrit during cardiopulmonary bypass with acute renal injury after coronary artery bypass surgery. Ann thorac Surg 2003; 76:784-91
222 SWAMINATHAN M, STAFFORD-SMITH M. Renal dysfunction after vascular surgery. Curr Opin Anaesthesiol 2003; 16:45-52
224 SYMONS JA, MYLES PS. Myocardial protection with volatile anaesthetic agents during coronary artery bypass surgery: a meta-analysis. Br J Anaesth 2006; 97:127-36
225 TALLGREN M, NIEMI T, PÖYHLÄ R, et al. Acute renal injury and dysfunction following elective abdominal aortic surgery. Eur J Vasc Endovasc Surg 2007; 33:550-5
226 TANAKA K, LUDWIG NM, KERSTEN JR, PAGEL PS, WARLTIER DC. Mechanisms of cardioprotection by volatile anesthetics. Anesthesiology 2004; 100:707-21
227 TANG IY, MURRAY PT. Prevention of perioperative acute renal failure: what works ? Best Pract Res Clin Anaesthesiol 2004; 18:91-111
228 TARAKJI KG, SABIK JF, BHUDIA SK, et al. Temporal onset, risk factors, and outcomes associated with stroke after coronary artery bypass grafting. JAMA 2011; 305:381-90
229 TRITAPEPE L, LANDONI G, GUARRACINO F, et al. Cardiac protection by volatile anaesthetics: a multicentre randomized controlled study in patients undergoing coronary artery bypass surgery grafting with cardiopulmonary bypass. Eur J Anaesthesiol 2007; 24:323-31
230 TUMAN KJ, McCARTHY RJ, NAJAFI RJ, IVANKOVICH AD. Differential effects of advanced age on neurologic and cardiac risks of coronary operations. J Thorac Cardiovasc Surg 1999; 104:1510-7
231 TUMLIN JA, FINKEL KW, MURRAY PT, et al. Fenoldopam mesylate in early acute tubular necrosis : a randomized, double-blind, placebo-controlled clinical trial. Am J Kidney Dis 2005 ; 46 :26-34
232 VAN DER LINDEN PJ. Cardioprotective effects of volatile anesthetics in cardiac surgery. Anesthesiology 2003; 99:516-7
233 Van Dijk D, Jansen EW, Hijman R, et al. Cognitive outcome after off-pump and on-pump coronary artery bypass graft surgery: a randomized trial. JAMA 2002; 287: 1405-12
234 VAN DIJK D, SPOOR M, HIJMAN R, et al. Cognitive and cardiac outcomes 5 years after off-pump vs on-pump coronary artery bypass graft surgery. JAMA 2007; 297:701-8
235 VAN WERMESKERKEN GK, LARDENOYE JWH, HILL SE, et al. Intraoperative physiologic variables and outcome in cardiac surgery. Part II. Neurologic outcome. Ann Thorac Surg 2000; 69:1077-83
236 VERRIER ED, DABAL RJ, HAMPTON C, et al. Myocardial protection strategies: Present and future. In: NEWMAN MF, ed. Perioperative organ protection. 2003 SCA monograph. Lippincott Williams & Wilkins 2003, 75-88
237 VISWESWARAN P, MASSIN EK, DUBOSE TD, et al. Mannitol-induced acute renal failure. J Am Soc Nephrol 1997; 8:1028-33
238 WAGENER G, BRENTJENS TE. Renal disease: The anesthesiologist’s perspective. Anesthesiol Clin N Am 2006; 24:523-47
239 WALL MH, ROYSTER RL. Pulmonary dysfunction after cardiopulmonary bypass: should we ventilate the lungs on pump ? Crit Care Med 2000; 28:1658-60
240 WELCH M, NEWSTEAD CG, SMYTH JV, et al. Evaluation of dopexamine hydrochloride as a renoprotective agent during aortic surgery. Ann Vasc Surg 1995; 9:488-92
241 WEST CA, NOEL AA, BOWER TC, et al. Factors affecting outcomes of open surgical repair of pararenal aortic aneurysms: A 10-year experience. J Vasc Surg 2006; 43:921-8
242 WESTERMAIER T, HUNGERHUBER E, ZAUSINGER S, et al. Neuroprotective efficacy of intra-arterial and intravenous magnesium sulfate in a rat model of transient focal cerebral ischemia. Acta Neurochir 2003; 145:393-9
243 WHITLOCK RP, CHAN S, DEVEREAUX PI, et al. Clinical benefit of steroid use in patients undergoing cardiopulmonary bypass : A meta-analysis of randomized trials. Eur Heart J 2008 ; 29 : 2592-600
244 WIJNEM MHWA, RAUMEN RMH, VADER HL, et al. A multioxydant supplementation reduces damage from ischemia reperfusion in patients after lower torso ischemia. A randomized trial. Eur J Vasc Endovasc Surg 2002; 23:486-90
245 WIJEYSUNDERA DN, BENDER JS, BEATTIE WS. Alpha-2 adrnergic agonists for the prevention of cardiac complications among patients undergoing surgery. Cochrane Database Syst Rev 2009; 7:CD004126
246 WYNN MM, MELL MW, TEFERA G, et al. Complications of spinal fluid drainage in thoracoabdominal aortic aneurysm repair: a report of 486 patients treated from 1987 to 2008. J Vasc Surg 2009; 49:29-35
247 YAO FSF, TSENG CCA, HO CYA, et al. Cerebral oxygen desaturation is associated with early postoperative neuropsychological dysfunction in patients undergoing cardiac surgery. J Cardiothorac Vasc Anesth 2004; 18:553-8
248 YAO FSF, TSENG CC, WU D, et al. Maintaining cerebral oxygen saturation during cardiac surgery decreased neurologic complications. Anesthesiology 2001; 95:A152
249 YELLON DM, HAUSENLOY DJ. Myocardial reperfusion injury. N Engl j Med 2007 ; 357 :1121-35
250 YMPA YP, SAKR Y, REINHART K, et al. Has mortality from acute renal failure decreased ? A systematic review of the literature. Am J Med 2005 ; 118 :827-32
251 YU CH, BEATTIE WC. The effects of volatile anaesthetics on cardiac ischemic complications and mortality in CABG: A meta-analysis. Can J Anaesth 2006; 53:906-18
252 ZAIDAN JR, KLOCHANY A, MARTIN WA, et al. Effect of thiopental on neurological outcome following coronary artery bypass grafting. Anesthesiology 1991; 74:406-11
253 Zangrillo A, Crescenzi G, Landoni G, et al. Off-pump coronary artery bypass grafting reduces postoperative neurologic complications. J Cardiothorac Vasc Anesth 2005; 19:193-6
254 ZAUGG M, LUCHINETTI E, SPAHN DR, et al. Differential effects of anesthetics on mitochondrial KATP channel activity and cardiomyocyte protection. Anesthesiology 2002; 97:15-23
255 ZAUGG M, SCHAUB MC, FOËX P. Myocardial injury and its prevention in the perioperative setting. Br J Anaesth 2004; 93:21-33
256 ZHAO ZQ, CORVERA JS, HALKOS ME, et al. Inhibition of myocardial injury by ischemic preconditioning during reperfusion : comparison with ischemic preconditioning. Am J Physiol Heart Circ Physiol 2003 ; 285 :H579-88
257 ZHURAV L, WILDES TS. Pro: Topical head cooling should be used during deep hypothermic circulatory arrest. J Cardiothorac Vasc Anesth 2012; 26:333-6